mQ Newsletter - February 11 2026
The Symposium Said It All
The 7th Annual HVAC/R Training Symposium in Ocoee, FL brought something different this year. More first-timers than ever. Vendors who showed to support the industry (not just to sell). The addition of the Bry-X stage opened room for more presentations and more knowledge sharing, and the collaborative format proved it belongs. The measureQuick booth was the busiest it's ever been: contractors signing up, existing users asking for implementation help, and a packed house for Jim Bergmann's presentation. By every measure, it was measureQuick's best year at this event.
For Jim, the personal highlight wasn't the presentation or the booth traffic. It was the number of technicians and owners who said measureQuick changed the trajectory of their career or their company. After a long stretch away from presenting, the Symposium was the perfect venue to re-engage, reconnect with old friends, and meet customers face-to-face for the first time. The vendor turnout reinforced something important: the industry is investing in quality, not just equipment. That's exactly where measureQuick lives.
Back to the Basics
Did measureQuick stall at your company last year? Maybe you signed up, ran a few tests, and it drifted. Maybe your techs reverted to old habits. You're not alone. The difference between companies that succeed with measureQuick and those that struggle comes down to one thing: getting the fundamentals right before chasing advanced features. The foundation is straightforward. Connect 9 probes, every time. Not 4. Not 6. Nine. Two pressure, three temperature clamps, two psychrometers, and two manometers. That's the measurement standard that unlocks a complete Vitals Score, and that score is what transforms a service call from opinion into documented proof of system performance.
The 9-probe standard exists because manufacturer kits with 6 probes leave gaps. You can verify refrigerant charge without measuring airflow, but you can't accurately diagnose a system. Static pressure, filter face velocity, and temperature split are the measurements most techs skip and most callbacks trace back to. If your team commits to deploying all 9 probes on every call, the Vitals Score does the rest: automated calculations, color-coded results, and a professional report your customers actually understand. Start there. Everything else builds on that foundation.
Upcoming Training Events
- Combo Class: mQ 101 + Champion
Canton, OH | February 12-13, 2026 | $850 | Limited to 15 Attendees - measureQuick 101: Cooling and Heat Pump Commissioning
Houston, TX (San Jacinto College) | February 17, 2026 | $99 - Advanced Class: Certified mQ Trainer & Champion
Houston, TX (San Jacinto College) | February 18-20, 2026 | $1,200 - measureQuick 101: Cooling and Heat Pump Commissioning
Versailles, KY (NAVAC Training Center) | March 10, 2026 | $99 - Master Class: Science Behind measureQuick, Plus Evacuation
Versailles, KY (NAVAC Training Center) | March 11-13, 2026 | $1,500 - Master Class: Science Behind measureQuick
Mogadore, OH (measureQuick HQ) | April 8-10, 2026 | $1,200 | Limited to 10 Attendees
Support Resources
Official Support
- Support Portal: https://support.measurequick.com/
- Phone: 234-813-9178
- Email: support@measurequick.zohodesk.com
Community Support
- Technical Discussions (open to all): Facebook Group
- Premier Services Support (unofficial): Facebook Group