mQ Newsletter - October 2026
A Running Burner Is Not a Tested Furnace
Heating calls are starting, and most furnaces on the schedule will light, run, and warm the house. None of that tells you whether the appliance is burning cleanly, venting properly, or firing at the input on its rating plate. Carbon monoxide gives no warning anyone can see or smell, and a visual inspection cannot tell you what is leaving the heat exchanger.
A combustion analyzer can. It measures oxygen, CO, CO2, flue temperature, and draft. Clocking the gas meter confirms input against the manufacturer's specification. The order you take those readings in is what makes the result hold up. The measureQuick® Combustion Quick Start Guide lays out a nine-step sequence:
- Verify safe ambient CO before anything else
- Start the appliance and check for spillage (atmospheric draft appliances)
- Set manifold pressure to the manufacturer's specification
- Verify input by clocking the meter
- Adjust manifold pressure within allowable limits
- Perform the combustion test
- Verify draft
- Set blower speed and verify temperature rise
- Verify combustion appliance zone (CAZ) depressurization is within limits
Steps 4 and 9 change what the other readings mean. Without clocking the meter, your combustion numbers describe an input you assumed. Without the CAZ test, you checked draft with the house at rest, but the appliance has to vent while the dryer, bath fans, and range hood pull the house negative.
The guide is a free eight-page PDF. It covers draft, CAZ pressure, CO thresholds, sampling locations, and gas meter clocking for gas appliances, fuel oil appliances, and domestic and commercial water heaters. Put a copy in every truck running heating calls this season.
In the app, the guided gas furnace and boiler workflow covers probe placement, testing, and the safety evaluation. Ambient, return, and supply CO show on a dedicated inspection screen. The Sauermann Si-CA 030 and Si-CA 130 analyzers connect directly. The workflow is open to every measureQuick user. Premier Services adds the HVAC Vitals score, benchmarking, and professional reports.
What Changed for Heating on October 2
The October update to measureQuick 3.6.3 (build 36884) reworked how the app handles combustion:
- CO and heating Vitals: CO air-free no longer lowers the heating Vitals score. It shows as a four-level condition indicator, and dangerous CO still fails the test.
- Stability indicator: shows when combustion readings have settled.
- Multi-cell furnaces: supported on the combustion page and in the report's combustion tables.
- Draft: insufficient draft now displays as below range.
- Equipment age deduction: stays stable for the whole test.
For service managers: heating scores from before and after October 2, 2026 are calculated differently, so compare like with like. If you benchmark technicians on heating scores, start that comparison from October 2.
Duct Airflow Traverse: Measured Airflow, Two Minutes
Airflow is the number the rest of a diagnosis leans on, in heating too: the temperature rise in step 8 above depends on it. Air does not move through a duct at one speed, so one reading in the center is an estimate. A traverse samples a grid of points and averages them.
The Duct Airflow Traverse, a quick test for Premier Services, runs that process for you:
- Layout: enter the duct width and depth, or capture them with the camera where supported. measureQuick shows where each access hole goes and how deep to insert the probe, using the Chebyshev method.
- Pacing: a countdown starts each hole and a beep moves you to the next point, so you watch the probe instead of the screen.
- Accuracy: extra readings where the air is turbulent, plus a density correction for temperature and humidity.
- Results: actual and standard CFM, with a heat map of the readings on its own report page.
In Jim Bergmann's demo, the full 25-point traverse took about two minutes.
measureQuick connects directly to the Testo 405i (in-duct hot wire), 410i (grille face velocity, with an Ak factor), 420 (as a hood, or in pressure-only mode as the manometer for a pitot tube traverse), 416 and 425, and works with the TEC DG-8 and a pitot tube. The Testo 605i supplies temperature and humidity for the density correction. Start from Quick Tests or the indoor airflow measurements.
Also in This Update
- Jobber: with Premier Services, measureQuick connects to Jobber, alongside ServiceTitan and Housecall Pro. A Jobber admin connects it from the Jobber App Store. Customer, job address, job details, technician assignment, and schedule come into measureQuick. Photos, PDF reports, and ACCA QI certificates go back to the Jobber job under Attachments. Measurement data stays in measureQuick.
- Multiple Superheat: works with every probe brand, picks up where you left off, and shows trend charts.
- Two-stage systems: set a system as two-stage in the system profile, and measureQuick flags it when the second stage is not engaging.
- PDF attachments (Premier Services): attach a Manual J or a duct leakage test in Photos, and measureQuick appends it to the report.
- Letter grades: the standard scale everywhere: 90 A, 80 B, 70 C, 60 D.
To update: the update installs over the air. In the app, tap the user icon in the upper left and check for updates.
Fall Training: Basics, Then Mastery
The process your team runs in January is the one they learned this fall. Two cities have the same two-step path: a Basics day for technicians, then Technical Mastery for whoever will train everyone else.
Newnan, GA: Progressive Training Lab
mQ Basics for Technicians | October 27
Full day, hands-on: account setup, Bluetooth probe pairing, refrigerant management, A/C and heat pump commissioning, airflow measurement, and report generation. Max 20 attendees. The preferred prerequisite for the next day.
mQ Technical Mastery and Company Implementation | October 28-30
Probe mapping, Install and Service workflows, the AI Profiler, Vitals scoring and benchmarking, static pressure screening, airflow measurement, and how to lead measureQuick training at your own company. $1,200, includes lunch Wednesday and Thursday. Max 10 attendees, minimum 5 to run.
Denver, CO: Stevens Equipment Supply
measureQuick Basics: HVAC Commissioning Training | November 10
A full day with Joe Medosch. Includes a measureQuick JB 9-probe kit to keep and a one-year Premier Services membership. Colorado contractors: the full cost is reimbursable through Power Ahead Colorado, up to six technicians per company. The October 15 session is sold out, so this is the next Denver date.
mQ Technical Mastery and Company Implementation | November 11-13
Same curriculum as Newnan, with hands-on electrical measurements, static pressure screening, and airflow measurement. $1,200, includes lunch Wednesday and Thursday. Max 10 attendees, minimum 5 to run.
Which fits? Technicians new to the app start with Basics. The service manager or lead tech who will train the rest of the team takes Technical Mastery, ideally after Basics. Questions to Joe Medosch at joe@measurequick.com.
Support Resources
Official Support
- Support Portal: https://support.measurequick.com/
- Phone: 234-813-9178
- Email: support@measurequick.zohodesk.com
Community Support
- Technical Discussions (open to all): Facebook Group
- Premier Services Support (unofficial): Facebook Group